Expansion module BAH 4000 for realising manual override of analogue outputs of controllers or DDC systems (real manual operating level). Typically used with valves, air flaps and variable frequency drives in HVAC systems. Each of the 0..10 V signals can be manually overridden using the switch (Auto-0V-10V-Poti) and potentiometer for adjusting the output voltage continously. The output voltage will be represented for visual monitoring purposes by the brightness of a LED. Every output is capable to drive a current of 10 mA. Furthermore, the module BAH 4000 provides a fixed-voltage output 10 V / 10 mA. When operating in automatic mode, the desired value of the output voltage will be sent to the BAH 4000 via the network variable nvi (SNVT_str_int), where the Bytes 2..5 belong to the analogue outputs 1 .. 4. Valid values are 0 .. 255 (correlating a range of 0 .. 100%). The actual values of output voltages as well as switches' position (Auto or 0V/10V/Poti) will be passed to the LON node via the network variable nvo (SNVT_str_int). Power supply (24 V DC) has to be connected to the BAH 4000 module via the spring-type terminals (41, 42) (see wiring interface). Regarding the configuration (adressing, maximum amount of expansion modules connected to a BZK, mounting, bus connection etc.), see chapter 'Configuration'. Module is also for use with BZK1000MOD (Modbus RTU). Important technichal data: Power Supply: +24 V DC via spring-type terminals
Die Karte BDH 1400 dient als Handbedienebene mit Notfunktion zur Ansteuerung von vier 1-stufigen Motoren (Auto-Aus-Hand) bzw. Klappen (2-Punktsteuerung, Auto-Zu-Auf). Jeder der 4 Kanäle verfügt über einen Relaisausgang (Wechsler) zur Ansteuerung von Leistungsschützen sowie über zwei LEDs zur Signalisierung von Stör-, Betriebs- oder Statusmeldungen. Die Ansteuerung der LEDs erfolgt über den Bus. Die LEDs 1, 3, 5 und 7 können sowohl rot/blinkend als auch grün/dauerleuchtend bzw. gelb-grün/blinkend angesteuert werden. Im Fall einer rot oder gelb leuchtenden LED wird am Zentralmodul eine Sammelstörmeldung ausgegeben; die LEDs 2, 4, 6 und 8 sind grün/dauerleuchtend ausgeführt. Die Information zur Ansteuerung der LEDs 1 - 8 wird in den Bytes 2 - 9 der Netzwerk-Eingangs-Variablen nvi (SNVT_str_int) an die Steuerkarte übertragen. Die Information zur Relais-Ansteuerung wird in den Bytes 10 bis 13 der Netzwerk-Eingangs-Variablen nvi (SNVT_str_int) an das BDH 1400 übergeben. Die Schalterstellung (Auto bzw. Aus/Hand oder Zu/Auf) wird in den Bytes 2 bis 5 der Netzwerk-Ausgangs-Variable nvo (SNVT_str_int) an den LON-Knoten übergeben. Bezüglich der Anlagenkonfiguration (Adressierung, maximale Anzahl von Erweiterungsmodulen an einem BZK, Montage, Busverbindungen etc.) sind die allgemeinen Hinweise im Kapitel Konfiguration zu beachten. Modul ist auch in Kombination mit dem BZK1000MOD (Modbus RTU) verwendbar.
Expansion module BDH 1401 for controlling four 1-state drives (real manual operating level). Each of the four channels provides a relay output (changeover contact) for activating contactors, and two LEDs for signalling Run and Fault status as well. The LEDs 1, 3, 5 and 7 are realised red/blinking and will cause a collective fault indicated on the BZK interface module; the LEDs 2, 4, 6 und 8 are realised green/steady light. Activating the LEDs (use +24 V DC) will be done by external potential-free contacts to be connected to the device via spring-type terminals. Status of LEDs and switches' position (Auto or off/manual) will be passed to the LON node via the network variable nvo (SNVT_str_int). Information for activating the relay outputs will be sent to the BDH1401 within the Bytes 2 .. 5 of the network variable nvi (SNVT_str_int). Regarding the configuration (adressing, maximum amount of expansion modules connected to a BZK, mounting, bus connection etc.), see chapter 'Configuration'. Module is also for use with BZK1000MOD (Modbus RTU). Important technichal data: Power Supply: +24 V DC via internal 8-pin system bus
Die Karte BDH1402 dient als Handbedienebene mit Notfunktion zur Ansteuerung von vier Klappenantrieben. Jeder der 4 Kanäle verfügt über einen Relaisausgang (Wechsler) zur Ansteuerung von Leistungsschützen sowie über zwei LEDs zur Signalisierung von Auf- und ZUmeldungen. Die LEDs SIND grün/dauerleuchtend ausgeführt. Die Ansteuerung der LEDs erfolgt mit +24 V DC durch externe potenzialfreie Kontakte, die über Klemmen auf die Karte aufgeschaltet werden. Der Status der LEDs sowie die Schalterstellung (Auto oder Aus/Hand) werden über den Bus und das Zentralmodul BZK1000LON an das LON Netzwerk übergeben, wo sie zur weiteren Verarbeitung zur Verfügung stehen. Bezüglich der Anlagenkonfiguration (Adressierung, maximale Anzahl von Erweiterungsmodulen an einem BZK, Montage, Busverbindungen etc.) sind die allgemeinen Hinweise im Kapitel Konfiguration zu beachten.
Die Karte BDH 1403 dient als Handbedienebene mit Notfunktion zur Ansteuerung von vier 1-stufigen Motoren.Jeder der 4 Kanäle verfügt über einen Relaisausgang (Wechsler) zur Ansteuerung von Leistungsschützen sowie über zwei LEDs zur Signalisierung von Stör- und Betriebsmeldungen. Die LEDs 1, 3, 5 und 7 sind rot/blinkend ausgeführt und bewirken bei Ansteuerung eine Sammelstörmeldung auf dem Zentralmodul; die LEDs 2, 4, 6 und 8 sind grün/dauerleuchtend ausgeführt. Die Ansteuerung der LEDs erfolgt mit +24 V DC durch externe potenzialfreie Kontakte mit Ruhestromschaltung, die über Klemmen auf die Karte aufgeschaltet werden.Der Status der LEDs sowie die Schalterstellung (Auto oder Aus/Hand) werden über die Netzwerk-Ausgangs-Variable nvo (SNVT_str_int) an den LON-Knoten übergeben.Die Information zur Relais-Ansteuerung wird in den Bytes 2 bis 5 der Netzwerk-Eingangs-Variablen nvi (SNVT_str_int) an das BDH 1401 übergeben. Bezüglich der Anlagenkonfiguration (Adressierung, maximale Anzahl von Erweiterungsmodulen an einem BZK, Montage, Busverbindungen etc.) sind die allgemeinen Hinweise im Kapitel Konfiguration zu beachten. Modul ist auch in Kombination mit dem BZK1000MOD (Modbus RTU) verwendbar.
Die Karte BDH 2200 dient als Handbedienebene mit Notfunktion zur Ansteuerung von zwei 2-stufigen Motoren (Auto-Aus-Stufe1-Stufe2) bzw. Klappen (3-Punktsteuerung, Auto-Halt-Auf-Zu). Die beiden Kanäle verfügen über je zwei Relaisausgänge (Wechsler) zur Ansteuerung von Leistungsschützen sowie über drei LEDs zur Signalisierung von Stör-, Betriebs- oder Statusmeldungen. Die Ansteuerung der LEDs erfolgt über den Bus. Die LEDs 1 und 4 können sowohl rot/blinkend als auch grün/dauerleuchtend bzw. gelb-grün/blinkend angesteuert werden. Im Fall einer rot oder gelb leuchtenden LED wird am Zentralmodul eine Sammelstörmeldung ausgegeben; die LEDs 2, 3, 5 und 6 sind grün/dauerleuchtend ausgeführt. Die Information zur Ansteuerung der LEDs 1 - 6 wird in den Bytes 2 - 7 der Netzwerk-Eingangs-Variablen nvi (SNVT_str_int) an die Steuerkarte übertragen. Die Information zur Relais-Ansteuerung wird in den Bytes 8 bis 11 der Netzwerk-Eingangs-Variablen nvi (SNVT_str_int) an das BDH 2200 übergeben. Die Schalterstellung (Auto bzw. Aus/St.1/St.2 oder Halt/Auf/Zu) wird in den Bytes 2 und 3 der Netzwerk-Ausgangs-Variable nvo (SNVT_str_int) an den LON-Knoten übergeben. Bezüglich der Anlagenkonfiguration (Adressierung, maximale Anzahl von Erweiterungsmodulen an einem BZK, Montage, Busverbindungen etc.) sind die allgemeinen Hinweise im Kapitel Konfiguration zu beachten. Modul ist auch in Kombination mit dem BZK1000MOD (Modbus RTU) verwendbar.
Die Karte BDH 2201 dient als Handbedienebene mit Notfunktion zur Ansteuerung von zwei 2-stufigen Motoren. Beide Kanäle verfügen über jeweils zwei Relaisausgänge (Wechsler) zur Ansteuerung von Leistungsschützen sowie über drei LEDs zur Signalisierung von Stör- und Betriebsmeldungen. Die LEDs 1 und 4 sind rot/blinkend ausgeführt und bewirken bei Ansteuerung eine Sammelstörmeldung auf dem Zentralmodul; die LEDs 2, 3, 5 und 6 sind grün/dauerleuchtend ausgeführt. Die Ansteuerung der LEDs erfolgt mit +24 V DC durch externe pozentialfreie Kontakte, die über Klemmen auf die Karte aufgeschaltet werden. Der Status der LEDs sowie die Schalterstellung (Auto bzw. Aus/Hand) werden über die Netzwerk-Ausgangs-Variable nvo (SNVT_str_int) an den LON-Knoten übergeben. Die Information zur Relais-Ansteuerung wird in den Bytes 2 bis 5 der Netzwerk-Eingangs-Variablen nvi (SNVT_str_int) an das BDH 2201 übergeben. Bezüglich der Anlagenkonfiguration (Adressierung, maximale Anzahl von Erweiterungsmodulen an einem BZK, Montage, Busverbindungen etc.) sind die allgemeinen Hinweise im Kapitel Konfiguration zu beachten. Modul ist auch in Kombination mit dem BZK1000MOD (Modbus RTU) verwendbar.
Das Modul SAH1010 dient zur Ansteuerung von vier Aktoren (Ventilen oder Klappen) mit einem 0..10V-Signal und zur Aufschaltung von vier Analogsignalen. In Verbindung mit einem Bedien-/Anzeigepanel SAH1020 entsteht eine Lokale Vorrangbedieneinrichtung (LVB). Jeder der 4 Kanäle verfügt über einen 0..10V-Analogausgang sowie über Klemmen zur Aufschaltung eines Analogsignals. Dieses kann sowohl ein 0..10V-Signal sein, als auch ein 0..20mA-Signal oder ein Widerstandsfühler. Zur Realisierung von Folgefunktionen stehen außerdem vier potentialgebundene Transistorausgänge (+24 V DC) zur Verfügung. Die Adressierung erfolgt durch einen Drehcodierschalter von 0 bis 15. Dadurch ist die maximale Anzahl von Modulen dieses Typs an einem Port auf 16 Stück beschränkt. Insgesamt können jedoch mehr als 16 Module an einer Schnittstelle betrieben werden, da sich die einzelnen Typen intern in der Adresse unterscheiden. Bezüglich der Anlagenkonfiguration (Bustopologie, Terminierung etc.) sind die allgemeinen Regeln bezüglich des Aufbaus von RS485-Netzen zu beachten.
Das Modul SAH1010 dient zur Ansteuerung von vier Aktoren (Ventilen oder Klappen) mit einem 0..10V-Signal und zur Aufschaltung von vier Analogsignalen. In Verbindung mit einem Bedien-/Anzeigepanel SAH1020 entsteht eine Lokale Vorrangbedieneinrichtung (LVB). Jeder der 4 Kanäle verfügt über einen 0..10V-Analogausgang sowie über Klemmen zur Aufschaltung eines Analogsignals. Dieses kann sowohl ein 0..10V-Signal sein, als auch ein 0..20mA-Signal oder ein Widerstandsfühler. Zur Realisierung von Folgefunktionen stehen außerdem vier potentialgebundene Transistorausgänge (+24 V DC) zur Verfügung. Die Adressierung erfolgt durch einen Drehcodierschalter von 0 bis 15. Dadurch ist die maximale Anzahl von Modulen dieses Typs an einem Port auf 16 Stück beschränkt. Insgesamt können jedoch mehr als 16 Module an einer Schnittstelle betrieben werden, da sich die einzelnen Typen intern in der Adresse unterscheiden. Bezüglich der Anlagenkonfiguration (Bustopologie, Terminierung etc.) sind die allgemeinen Regeln bezüglich des Aufbaus von RS485-Netzen zu beachten.
The module MAH1030 (consisting of one MAH1010 and MAH1020) serves as local override / indication device (LO/ID) providing four analog outputs 0...10 Volts. It is used where the analog outputs of DDC/PLC systems may need to be overridden by manual intervention. Typical applications in the sector of HVAC are, e.g., valves, dampers and frequency converters. The analog output module MAH1010 provides four analog outputs 0...10 V. The maximum load of each output is 10 mA. In addition, it provides four analog inputs which can be configured for various types of signals, among them 0...10 V, 0...20 mA, and different types of resistance sensors. In order to offer the possibility of manual override of the outputs, a front module is connected to the DIN rail mounted device MAH1010 via a pluggable cable. For each channel, the front module provides a switch that allows the automatic signal to be overridden (‘Automatic’ – ‘0 Volts’ – ‘Pot’), a potentiometer for continuous manual adjustment of the output voltage and an LED in light / dark operating mode (green), optionally configurable with color change from green over orange to red, for visual control of the output voltage. Setting the required value of an analog output usually will be done via MODBus commands. Alternatively, however, in a configuration register the option can be defined that the analog outputs will be controlled by signals which are connected via terminals to the corresponding analog inputs. The status of the analog inputs and the current position of the switches ('Automatic' or 'Off / potentiometer') will be transferred via MODBus to the MODBus master device (DDC/PLC) where they are available for further processing. Regarding the system configuration (addressing, maximum number of modules connected to a MODBus Master interface, installation, connection to the bus etc.), please follow the instructions in the chapter Configuration.
Das Modul SBZ1010 dient als Lampentest- und Sammelstör-/Quittiermodul für die anderen an den Bus angeschlossenen Module. In Verbindung mit einem Bedien-/Anzeigepanel SDH1020 entsteht eine Lokale Vorrangbedieneinrichtung (LVB). Das SBZ1010 verfügt über drei Relaisausgang (Schließer) zur Ansteuerung von externem Lampentest, einer externen Hupe und um ein Reset-Signal potentialfrei auszugeben. Diese Relais können sowohl über den Bus aktiviert werden als auch durch die Aufschaltung eines +24V-Signals über Klemmen. Die Adressierung ist nicht änderbar, sondern fest. Aus diesem Grund kann jeweils nur ein einziges Modul dieses Typs an einem Port betrieben werden. Bezüglich der Anlagenkonfiguration (Bustopologie, Terminierung etc.) sind die allgemeinen Regeln bezüglich des Aufbaus von RS485-Netzen zu beachten.
Depending on the configuration, the lamp test module MBZ1030 (consisting of one MBZ1010 and MBZ1020) provides and performs the following functions: - Lamp testing of all connected expansion modules - Possibility of signaling a collective fault message which has been generated in the MX system by means of a LED at the door module. The LED will be controlled via MODBus; it is recommended to use LED 1 for this purpose as definitely this LED will signalize a collective fault message during autonomous operation without a MODBus master (DDC/PLC) - Relay contact (NO) for connecting an external horn - Acknowledging fault messages and release after faults - Monitoring and displaying the status of MODBus communication - Automatically switches from slave mode to master mode if no MODBus telegrams have been received for a certain time. Depending on the configuration of the operating mode, DI4 must be activated additionally. That way, an autonomous fault monitoring system is realized during bus failure. Autonomous operating mode without external master will be signalized at the front module by the second LED. Therefore, even when operating in slave mode, this LED should not be assigned to another message. Regarding the system configuration (addressing, maximum number of modules connected to a MODBus Master interface, installation, connection to the bus etc.), please follow the instructions in the chapter Configuration.
Das Modul SDH1010 dient zur Ansteuerung von vier 1-stufigen Antrieben (Motoren oder Klappen) und zur Aufschaltung der zugehörigen Betriebs- und Störmeldungen. In Verbindung mit einem Bedien-/Anzeigepanel SDH1020 entsteht eine Lokale Vorrangbedieneinrichtung (LVB). Jeder der 4 Kanäle verfügt über einen Relaisausgang (Wechsler) zur Ansteuerung von Leistungsschützen sowie über Klemmen zur Aufschaltung von bis zu drei Meldungen wie Stör- oder Betriebsmeldung pro Antrieb. Die Ansteuerung erfolgt mit +24 V DC durch externe potentialfreie Kontakte, die über Klemmen auf die Karte aufgeschaltet werden. Zur Realisierung von Folgefunktionen stehen außerdem vier potentialgebundene Transistorausgänge (+24 V DC) zur Verfügung. Die Adressierung erfolgt durch einen Drehcodierschalter von 0 bis 15. Dadurch ist die maximale Anzahl von Modulen dieses Typs an einem Port auf 16 Stück beschränkt. Insgesamt können jedoch mehr als 16 Module an einer Schnittstelle betrieben werden, da sich die einzelnen Typen intern in der Adresse unterscheiden. Bezüglich der Anlagenkonfiguration (Bustopologie, Terminierung etc.) sind die allgemeinen Regeln bezüglich des Aufbaus von RS485-Netzen zu beachten.
The module MDH1030 (consisting of one MDH1010 and MDH1020) serves as local override / indication device (LO/ID) for the control of up to four single-stage drives. Each of the four channels provides a relay output (changeover contact) for controlling power contactors, and two LEDs for indication of fault and operational feedback messages. The LEDs 1, 3, 5 and 7 may be configured green, red or orange. For these four digital inputs there is a register available which provides three pieces of information for every DI. Namely, these are the current state of the DI, and whether a message has accrued newly (‘new incident’) or already was been acknowledged, provided the message is configured as a fault message. The selected LED color is not relevant for this function. If the memory for fault messages of one of these digital inputs is activated, in the mentioned register the bit 'new incident' is set when a new fault message accrues (every digital input has its assigned bits in the register). When the fault message is acknowledged (via push button at the module or via MODBus command), in addition to the bit ‘new incident’, the corresponding bit ‘fault acknowledged’ will be set, provided the fault is still present. If the fault message is no longer active, the bits are just reset to zero. However, if the fault disappeared before acknowledged, the bit ‘new incident’ will still remain set until the fault message has been acknowledged. The LEDs 2, 4, 6 and 8, in contrast, will always be lit green, without memory for fault messages. The control of the digital inputs will be done with 24 V DC switched by external dry contacts that are connected to the module via terminals. The reference potential is defined via the COM terminals in groups and can be both, 0 volts and +24 Volts (DC). Using the settings in MODBus registers, you can select open circuit or closed-circuit principle for each input separately. The status of the digital inputs and the current position of the switches (‘Automatic’ or ‘Off / manually’) will be transferred via MODBus to the MODBus master device (DDC/PLC) where they are available for further processing. However, the LEDs of the front module can also be configured so that they are controlled via MODBus commands. The digital inputs (terminals) can be used anyway, but in this case without signaling at the front module. Activating the relays of the digital outputs usually is done via MODBus commands. Alternatively, however, in a configuration register the option can be defined that the relays will be controlled by signals which are connected via terminals to the corresponding digital inputs. The conditional outputs (ground referenced, +24 V) also will be controlled via MODBus commands unless the option ‘Controlling the conditional outputs depending on DI’s status’ is selected. For details on this feature, see the corresponding configuration register. Regarding the system configuration (addressing, maximum number of modules connected to a MODBus Master interface, installation, connection to the bus etc.), please follow the instructions in the chapter Configuration.
Das Modul SDH1210 dient zur Ansteuerung von zwei 2-stufigen Antrieben (Motoren oder Klappen) und zur Aufschaltung der zugehörigen Betriebs- und Störmeldungen. In Verbindung mit einem Bedien-/Anzeigepanel SDH1220 entsteht eine Lokale Vorrangbedieneinrichtung (LVB). Jeder der 2 Kanäle verfügt über zwei Relaisausgänge (Wechsler) zur Ansteuerung von Leistungsschützen sowie über Klemmen zur Aufschaltung von bis zu sechs Meldungen wie Stör- oder Betriebsmeldung pro Antrieb. Die Ansteuerung erfolgt mit +24 V DC durch externe potentialfreie Kontakte, die über Klemmen auf die Karte aufgeschaltet werden. Zur Realisierung von Folgefunktionen stehen außerdem vier potentialgebundene Transistorausgänge (+24 V DC) zur Verfügung. Die Adressierung erfolgt durch einen Drehcodierschalter von 0 bis 15. Dadurch ist die maximale Anzahl von Modulen dieses Typs an einem Port auf 16 Stück beschränkt. Insgesamt können jedoch mehr als 16 Module an einer Schnittstelle betrieben werden, da sich die einzelnen Typen intern in der Adresse unterscheiden. Bezüglich der Anlagenkonfiguration (Bustopologie, Terminierung etc.) sind die allgemeinen Regeln bezüglich des Aufbaus von RS485-Netzen zu beachten.
The module MDH1230 (consisting of one MDH1210 and MDH1220) serves as local override / indication device (LO/ID) for the control of two double-stage drives. Both channels provide two relay outputs each (changeover contact) for controlling power contactors, and three LEDs for indication of fault and operational feedback messages. The upper LED of each channel may be configured green, red or orange. For these two digital inputs there is a register available which provides three pieces of information for every DI. Namely, these are the current state of the DI, and whether a message has accrued newly (‘new incident’) or already was been acknowledged, provided the message is configured as a fault message. The selected LED color is not relevant for this function. If the memory for fault messages of one of these digital inputs is activated, in the mentioned register the bit 'new incident' is set when a new fault message accrues (every digital input has its assigned bits in the register). When the fault message is acknowledged (via push button at the module or via MODBus command), in addition to the bit ‘new incident’, the corresponding bit ‘fault acknowledged’ will be set, provided the fault is still present. If the fault message is no longer active, the bits are just reset to zero. However, if the fault disappeared before acknowledged, the bit ‘new incident’ will still remain set until the fault message has been acknowledged. The LEDs 2, 3, 5 and 6, in contrast, will always be lit green, without memory for fault messages. The control of the digital inputs will be done with 24 V DC switched by external dry contacts that are connected to the module via terminals. The reference potential is defined via the COM terminals in groups and can be both, 0 volts and +24 volts (DC). Using the settings in MODBus registers, you can select open circuit or closed-circuit principle for each input separately. The status of the digital inputs and the current position of the switches ('Automatic' or 'Off / manually') will be transferred via MODBus to the MODBus master device (DDC/PLC) where they are available for further processing. However, the LEDs of the front module can also be configured so that they are controlled via MODBus commands. The digital inputs (terminals) can be used anyway, but in this case without signaling at the front module. Activating the relays of the digital outputs usually is done via MODBus commands. Alternatively, however, in a configuration register the option can be defined that the relays will be controlled by signals which are connected via terminals to the corresponding digital inputs. The conditional outputs (ground referenced, +24 V) also will be controlled via MODBus commands unless the option ‘Controlling the conditional outputs depending on DI’s status’ is selected. For details on this feature, see the corresponding configuration register. Regarding the system configuration (addressing, maximum number of modules connected to a MODBus Master interface, installation, connection to the bus etc.), please follow the instructions in the chapter Configuration.
Das Modul SLM1010 dient zur Aufschaltung von bis zu 16 Betriebs- oder Störmeldungen. In Verbindung mit einem Bedien-/Anzeigepanel SLM1020 entsteht eine Lokale Vorrangbedieneinrichtung (LVB). Zur Realisierung von Folgefunktionen stehen außerdem vier potentialgebundene Transistorausgänge (+24 V DC) zur Verfügung. Die Adressierung erfolgt durch einen Drehcodierschalter von 0 bis 15. Dadurch ist die maximale Anzahl von Modulen dieses Typs an einem Port auf 16 Stück beschränkt. Insgesamt können jedoch mehr als 16 Module an einer Schnittstelle betrieben werden, da sich die einzelnen Typen intern in der Adresse unterscheiden. Bezüglich der Anlagenkonfiguration (Bustopologie, Terminierung etc.) sind die allgemeinen Regeln bezüglich des Aufbaus von RS485-Netzen zu beachten.